Catalogue NPPD sd

Next:

Catalogue MJP-SDC sd

NPPD is Positive Displacement (Volumetric), Rotating Piston design water meter with Super Dry Type Register from size 5/8X1/2” to 2” designed by NWM and meets to AWWA C700 with NSF-61 Certification..

OPERATION:

Water flows through the meter’s strainer and into the measuring chamber where it drives the piston. The hydro dynamically balanced piston rotates guided by a division plate. A driving magnet transmits the movement of the piston to a driven magnet located within the hermetically sealed register. The magnet is connected to   gear  train  which  translates  the  piston  rotate into  volume  totalizators displayed on the register dial face.

CONSTRUCTION:

PPD bottom loaded Water Meter consists of three basic components: main case, measuring chamber and a sealed register. The main cases of all sizes are constructed using Brass Alloy or Bronze Alloy or Lead free Brass Alloy. Measuring Chambers are constructed of a durable synthetic polymer. Bottom plates are Brass Alloy. Registers are available as either direct read or electronic output with Plastic Register Cover and plastic Register Shroud, Brass Register Cover and brass Register Shroud upon your request.


Dimension and Dial Plate Design for USG (CF and m3 AS OPTION) with NSF approval mark:


Size

5/8*1/2

5/8*3/4”

3/4” Short

3/4*3/4”

3/4*1”


1

1-1/2”

2”

L

7-1/2”

7-1/2”


7-1/2”

9

9


10-3/4

13

17

D

3/4”

1”



1”

1”

1-1/4”

1-1/4

Flange

Flange

W



3-13/16”




4-3/8”


5-3/4”

6”

H



4-3/4”




5-1/8”


6-1/4”

6-3/4”

Main Technical Data:




Size



inch

5/8*1/2”

3/4 Short

1

1-1/2”

2”


5/8X3/4”

3/4X3/4”

X

X


X



X

3/4X1”

X

X


X

High Flow Rate

USGPM

20

30

50

100


160

Continuous Flow Rate

USGPM

10

15

25

50


80

Low Flow Rate

USGPM

1/4

1/2

3/4

1-1/2


2

Normal Flow Rate Range

USGPM

1-20

2-30

3-50

5-100

8-160

Max. Working Pressure

PSI

150

150

150

150


150

Max. Temperature

Deg. F

122

122

122

122


122

Max. reading

USG


9999999.99


999999999.9

Min. reading

USG


0.01




0.1

Max. reading

CF


999999.999


99999999.99

Min. reading

CF


0.001




0.01

Max. reading

m3


99999.9999


999999.999

Min. reading

m3


0.0001



0.001


Max. Permission Error:

Normal Flow Limits: Within the normal flow rate range, the meter shall register

not less than 98.5% and not more than 101.5% of the water actually passed through

the meter;

Low Flow Limits: the meter shall register not less than 95% and not more than 101%

of the water actually passed through the meter.

Head Loss Curve and Accuracy Curve:



 Catalogue NPPD sd